1. Product Information
DCT1158W is a widely used, versatile, clamp-on, transit-time ultrasonic flowmeter, It has a very simple installation, without breaking the tube, no disruption of water supply, enables customers to easily implement flexible pipe flow measurement, products can also be equipped with a permanent clamp-on installation, without daily maintenance,long-term to provide credible, no deviation measurement. It uses the most advanced digital technologies and intelligent adaptive acoustic technology, measurement stability make it more prominent, At the same time, it uses a focused acoustic patented, make the products in the continuous measurement of reception quality was significantly enhanced.
DCT1188W Standard configuration as shown: ① Transmitter ② Sensors
③Brass ball valve④ Carbon steel base
DCT1158W series products are made up of transmitter and sensor. Insertion sensors can be Online installation with pressure, it has the advantage of firm installation and the scene without shutdown ,etc. Are particularly well suited for measuring small amounts of single liquid medium containing the particles and air bubbles.
DCT1158W uses an advanced modular design, independent menu operation, LCD backlit display, product transmitter protection grade reaches IP65, Suitable for harsh environments such as moisture and soaking.
DCT1158W collection of the current RS485 / RS232 communication interface used in industrial applications,4-20mA current signal, pulse output ,Modbus protocol, DC/ AC power, support product all-weather work, may constitute a flow measurement network requirements. In addition, the product can be extended to use solar energy, mine supply (Rem power) explosion and other functional modules, so that products can meet a variety of application environments.
The 2014 version DCT1158W series ultrasonic flowmeter, use of the currently most popular golden material, good sense and high pressure plastic fuselage, strong and lightweight, dual-function keys, Operation more efficient, simple, convenient, also uses a new FPGA delay line measurement techniques, with high dynamic advantages, sampling rate of 200 times / sec.
2. Features
Online installation with pressure
Calibration and maintenance of on-site without having to shut down.
Positive and negative flow measurement, the cumulative measure
Keyboard keys life of more than 200,000 times.
No fault working time 50000 hours test
3. Apply to the fluid
Suitable for pure liquid, In the liquid without impurities, particles, suspended matter and bubbles, and it is full pipe flow measurement
4. Apply pipe
Carbon steel
stainless steel
PVC
Cast iron
5.application
★ Water (hot water, chilled water, city water, sea water, waste water, etc.);
★ Sewage with small particle content;
★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);
★ Chemicals (alcohol, acids, etc.);
★ Plant effluent;
★ Beverage, liquid food;
★ Ultra-pure liquids;
★ Solvents and other liquids
6.Specifications
Model | Description |
DCT1158W |
DCT1158W Economical insertion type ultrasonic flowmeter Installation:Wall Mount Flow Range:0~5m/s Accuracy:± 1% of measured value Repeatability:0.2% Keyboard:16(4*4)Touch of a button Display:20*2Dot matrix characters Power supply: 10~36VDC,1A Max Case material:IP65,Cast aluminum Analog Output:4-20mA output,Maximum load 750 Ω OCT pulse output:0-5000Hz Ambient temperature: -10℃~+50℃ Relative humidity:0~99%Non-condensing Communications:RS-485 communication Interface, Modbus protocol Material: ABS/PC plastic |
A | I/O option |
1 | 4-20mA output, OCT pulse output, RS-485communication interface |
E | GPRS function |
B | Transmitter Chassis |
1 | Shell:IP65,ABS/PC plastic |
2 | Explosion-proof enclosure, Ex dⅡBT4 |
3 | Explosion-proof enclosure, Ex dⅡCT4 |
4 | Explosion-proof enclosure, Ex dⅡBT6 |
5 | Explosion-proof enclosure, Ex dⅡCT6 |
C | Transducer |
W |
Normal temperature insertion sensor Installation: Insertion Diameter range can be measured:50mm~1200mm Sensor cable length:9m shell of probe: stainless steel .PEI .The base:Carbon. Ball valve:Brass Operating Temperature:-40℃~+80℃ |
WH |
High temperature insertion sensor Installation: Insertion Diameter range can be measured:50mm~1200mm Sensor cable length:9m Probe the shell:Stainless steel\PEI. The base:Carbon. Ball valve:Brass Operating Temperature:-40℃~+150℃ |
D | Power Converters |
1 | No need |
2 | Needs(input220V,output12V,Load current 1A |
E | Cable length |
009 | Standard cable length:9m |
XXX | Sensor cable length:Every 5 meters for a longer unit,Can be extended up to 305m. |
Transmitter Wiring
Transmitter Size
Sensor Size(mm)
W210-type small insertion sensor(standard)
Explosion levels: E x ia ⅡBT4
Weight: 4.5kg (With cable,one to one)
WH- type High temperature insertion sensor
Explosion levels: E x ia ⅡBT4
Weight: 10kg (With cable,one to one)
Explosion-proof enclosure
BXK-T Explosion-proof enclosure(mm)
Explosion levels: Ex dⅡBT4
Ex dⅡCT4
Ex dⅡBT6
Ex dⅡCT6
Electrical Interface:4×G1/2“
Lightning protection power supply(mm)
Lightning protection power supply (Rem Power)
Power supply lightning protection performance:
Lightning protection level: Ⅱ (IEC EN 61643-11.2001)
Nominal voltage:AC85~265V/50Hz
The maximum continuous operating voltage AC 265V
Working temperature: -40 /85 C
In the lightning current <20KA conditions to ensure self-recovery capability 20 times
Ultrasonic sensors lightning protection performance:
Nominal operating voltage DC 36V
The maximum continuous operating voltage DC 42V
The maximum transmission bandwidth: 5MHz
In the lightning current <20KA conditions to ensure self-recovery capability 20 times
Installation, site selection
V-type installation method is applicable diameter range50mm-500mm (on the same side, the choice of site should not be installed at the top or bottom of the pipe)
Z-type installation method is applicable diameter range 100mm-600mm(on the same side, the choice of site should not be installed at the top or bottom of the pipe)
Installation diagram
90 degree bend |
T-Tee |
Diffuser |
Orifice |
Regulating valve |
Pumps |
Vertical mounting |
Site selection principles
1. Should avoid clock 6 or 12 point position, so as to avoid sediment at the bottom of the pipe or pipes upper part of the bubble, air-pocket caused by signal attenuation.
2. Fully considering the tube wall scaling condition, as far as possible choose no scaling section measuring, can fully meet, need to think about scaling for lining in order to get better the measurement accuracy.
Accuracy:0.2
UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
UCT3488D Multi-channel ultrasonic flowmeter
Accuracy:0.5
DCT1188C multifunctional clamp-on type ultrasonic flowmeter
DCT1188W multifunctional insertion type ultrasonic flowmeter
DCT1288i High dynamic response of portable type ultrasonic flowmeter
Accuracy:1.0
DCT1158C Economical clamp-on type ultrasonic flowmeter
DCT1158SE Battery-powered type ultrasonic flowmeter
DCT1158W Economical insertion type ultrasonic flowmeter
DCT1258 Handheld Type Ultrasonic Flowmeter
Accuracy:1.5
DCT1158SE Battery-powered Insertion type ultrasonic flowmeter
DCT1438K Buckle -measured type ultrasonic flowmeter
Heat(cold)meters
HCM1158LH Buildings dedicated type heat(cold)meters
HCM1158LH-K Central air-conditioning of buildings dedicated meter
HCM1188H Multifunctional type Ultrasonic Heat Meters
HCM1438LS Heat (cold)Meters