DCT1188C multifunctional clamp-on ultrasonic flowmeter
  DCT1188C is a widely used, versatile, clamp-on, transit-time ultrasonic flowmeter, It has a very simple installation.
Description

  1. Product Information
         
  DCT1188C is a widely used, versatile, clamp-on, transit-time ultrasonic flowmeter, It has a very simple installation, without breaking the tube, no disruption of water supply, enables customers to easily implement flexible pipe flow measurement, products can also be upgraded to a permanent clamp-on installation, without daily maintenance,long-term to provide credible, no deviation measurement. It uses the most advanced digital technologies and intelligent adaptive acoustic technology, measurement stability make it more prominent, At the same time, it uses a focused acoustic patented, make the products in the continuous measurement of reception quality was significantly enhanced.

  DCT1188C Standard configuration as shown above

  ① Transmitter②Sensor③Tube bundle

  ④Coupling agent⑤Fixing screws⑥SD Card Reader

  DCT1188C is made up of transmitter and sensor ,Clamp-on sensors wi.h a simple to install, no broken pipes, and other characteristics, esecially suitable for strong toxic and corrosive medium, and the flow measurement of various kinds of pressure requirements, this installation has no moving parts, compared with the traditional measuring machine, it has the remarkable characteristics of high reliability and low maintenance rate

  DCT1188C uses an advanced modular design, independent menu operation, LCD backlit display, product transmitter protection grade reaches IP65, Suitable for harsh environments such as moisture and soaking.

  DCT1188C collection of the current RS485 / RS232 communication interface used in industrial applications,4-20mA current signal, pulse output ,Modbus protocol, DC/ AC power, support product all-weather work, may constitute a flow measurement network requirements. In addition, the product can be extended to use solar energy, lightning protection power supply (Rem power) , explosion-proof and other functional modules, So that products can meet a variety of application environments.

  DCT1188 has a powerful WiFi function, more convenient and efficient. Flowmeter can be used as a WIFI hotspot host, send messages to each user terminal in accordance with DCP / IP protocol ,such as the instrument measured field parameters and instrument status information,etc. Users to use mobile phones, tablet, laptop and other WiFi-enabled terminal tool with access to the flow, read user information required

  SD card storage, Improve product reliability measurement.

  Equipped with SD card mass storage, can record every moment of traffic data changes (Record up to 512 days of historical data), greatly improving the reliability of the cumulative number of data

  2.Features

   Clamp-on installation, easy and convenient, without breaking the pipe installation.

  Calibration and maintenance of on-site without having to shut down.

   8.8 million sets of data storage

   Time between failures 50,000 hours testing.

  Off flow compensation

  Sub-period traffic statistics, quantitative monitoring.

     Keyboard keys life of more than 200,000 times.

   Tensile strength of 800 Newton sensor cable

   Sensor cable signal attenuation -90dB / 100M.

   Powerful WiFi function, more convenient and faster.

  3. Apply to the fluid

  Suitable for pure liquid, In the liquid without impurities, particles, suspended matter and bubbles, and it is full pipe flow measurement

  4. Apply pipe

   Carbon steel

  stainless steel

  PVC

    Cast iron

 5.application

  ★ Water (hot water, chilled water, city water, sea water, waste water, etc.);

  ★ Sewage with small particle content;

  ★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);

  ★ Chemicals (alcohol, acids, etc.);

  ★ Plant effluent;

  ★ Beverage, liquid food;

  ★ Ultra-pure liquids;

  ★ Solvents and other liquids

  6.Specifications

Model Description
 
 
 
 
 
DCT1188C
DCT1188C multifunctional clamp-on ultrasonic flowmeter
Installation:Wall Mount
Equipped with SD card mass storage, record up to 512 days of historical data
Flow Range:0~± 12m/s
Accuracy:0.5%
Repeatability:0.1%
Keyboard:16(4*4)Touch of a button
Display:20*2Dot matrix characters
Power supply:90~250VAC/48~63Hz/10~36VDC/10~24VAC
Case material:IP65,Cast aluminum
Output:OCT pulse output,Relay output,4-20mA output
Communications:RS-232/RS-485 Communication Interface, Modbus protocol
WIFI function:The DIP switch to the ON state ,About 10-15s open after normal boot WiFi module
A I/O option
3 4-20mA output, OCT pulse output, Relay output,
RS-232 /485①Modbus protocol
E GPRS function
B Transmitter Chassis
1 Shell:IP65,Cast aluminum chassis
2 Explosion-proof enclosure, Ex dⅡBT4
3 Explosion-proof enclosure, Ex dⅡCT4
4 Explosion-proof enclosure, Ex dⅡBT6
5 Explosion-proof enclosure, Ex dⅡCT6
C Transducer
C Normal temperature sensor
Installation: clamp-on
Diameter range can be measured:25mm~5000mm
Sensor cable length:9m
Probe the shell:Zinc Alloy.PEI
Operating Temperature:-40℃~+80℃
C020 Normal temperature combined sensor
Installation: clamp-on/ Permanent clamp-on
Diameter range can be measured:25mm~5000mm
Sensor cable length:9m
Probe the shell:Stainless steel
Operating Temperature:-40℃~+80℃
 

 
CH High temperature sensor
Installation: clamp-on
Diameter range can be measured:25mm~5000mm
Sensor cable length:9m
Probe the shell:Stainless steel\PEI
Measuring medium temperature:-40℃~+150℃

 
MC Permanent clamp-on sensor
Installation:  permanent clamp-on
Diameter range can be measured:65mm~2000mm
Sensor cable length:9m
Probe the shell:Zinc Alloy/PEI, Base:Carbon
Measuring medium temperature:-40℃~+80℃
D Explosion levels
N  
1 E x ia ⅡBT4
E Cable length
009 Standard cable length:9m
XXX Sensor cable length:Every 5 meters for a longer unit,Can be extended up to 305m.

  Transmitter Wiring

 

  Transmitter Size

 

DCT1188CTransmitter size shape
 

  Sensor Size(mm)

  C- type Clamp-on sensor(Standard)

  Shell material: Alloy die casting

  Explosion levels: E x ia ⅡBT4

  Medium temperature: -40℃~+80℃

  Weight: 4kg (With cable)

  CH- type High temperature Clamp-on sensor

  Shell material: Alloy die casting

  Explosion levels: E x ia ⅡBT4

  Medium temperature: -40℃~+150℃

  Weight: 4.5kg (With cable)

  MC- type Permanent clamp-on sensor

  Welded shell material: Carbon steel (optional stainless steel)

  Explosion levels: E x ia ⅡBT4

  Medium temperature: -40℃~+80℃

  C020-Type Normal temperature combined sensor

  Shell material: stainless steel

  Medium temperature: -40℃~+80℃

  Explosion-proof enclosure

  BXK-T Explosion-proof enclosure(mm)

  Explosion levels: Ex dⅡBT4

  Ex dⅡCT4

  Ex dⅡBT6

  Ex dⅡCT6

  Electrical Interface:4×G1/2“

  Lightning protection power supply(mm)

  Lightning protection power supply (Rem Power)

  Type:FFH-001

  Power supply lightning protection performance:

  Lightning protection level: Ⅱ (IEC EN 61643-11.2001)

  Nominal voltage:AC90~245V,50/60Hz

  The maximum continuous operating voltage AC 265V

  Working temperature: -40 ~ + 60 C

  In the lightning current <20KA conditions to ensure self-recovery capability 20 times

  Ultrasonic sensors lightning protection performance:

  Nominal operating voltage DC 36V

  The maximum continuous operating voltage DC 42V

  The maximum transmission bandwidth: 5MHz

  In the lightning current <20KA conditions to ensure self-recovery capability 20 times

  Installation, site selection

  V-type installation method is applicable diameter range 25mm-500mm(The opposite side, the choice of site should not be installed at the top or bottom of the pipe)

  Z-type installation method is applicable diameter range100mm-5000mm (The opposite side, the choice of site should not be installed at the top or bottom of the pipe)

 

  Installation diagram

90 degree bend
T-Tee
Diffuser
Orifice
Regulating valve
Pumps
Vertical mounting

  Site selection principles

  1. Should avoid clock 6 or 12 point position, so as to avoid sediment at the bottom of the pipe or pipes upper part of the bubble, air-pocket caused by signal attenuation.

  2. Fully considering the tube wall scaling condition, as far as possible choose no scaling section measuring, can fully meet, need to think about scaling for lining in order to get better the measurement accuracy.

Accuracy0.2
UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
UCT3488D Multi-channel ultrasonic flowmeter
 
Accuracy0.5
DCT1188C multifunctional clamp-on type ultrasonic  flowmeter
DCT1188W multifunctional insertion type ultrasonic flowmeter
DCT1288i High dynamic response of portable type ultrasonic flowmeter
 
Accuracy1.0
DCT1158C Economical clamp-on type ultrasonic flowmeter
DCT1158SE Battery-powered type ultrasonic flowmeter
DCT1158W Economical insertion type ultrasonic flowmeter
DCT1258 Handheld Type Ultrasonic Flowmeter
 
Accuracy1.5
DCT1158SE Battery-powered Insertion type ultrasonic flowmeter
DCT1438K Buckle -measured type ultrasonic flowmeter
 
Heatcoldmeters
HCM1158LH Buildings dedicated type heat(cold)meters
HCM1158LH-K Central air-conditioning of buildings dedicated meter
HCM1188H Multifunctional type Ultrasonic Heat Meters
HCM1438LS Heat (cold)Meters

saleMan 1:
saleMan 2:
saleMan 3:
saleMan 4: