DCT1258 Handheld Ultrasonic Flowmeter
  DCT 1 258 Handheld ultrasonic flowmeter is a wide range of applications, transit-time type ultrasonic flowmeter .
Description

  1. Product Information

  DCT 1 258 Handheld ultrasonic flowmeter is a wide range of applications, transit-time type ultrasonic flowmeter . It is compact and lightweight, rechargeable battery and universal power supply is designed so that you can achieve anywhere pipeline measure .It uses the most advanced digital technologies and intelligent adaptive acoustic technology, make the measurement stability more prominent. At the same time, it uses a focused acoustic patented, make the products in the continuous measurement of reception quality was significantly enhanced

  DCT1258 Standard configuration as shown: ① Transmitter ② Sensors Cable (5m)

  ③4-20A Signal line ④Suitcase

  ⑤Chargers ⑥Coupling agent

  ⑦Stainless steel chain

  DCT 1 258 Handheld ultrasonic flowmeter is made up of transmitter and sensor. Magnetic clamp

  probe installation simple , continuous measurement can be adsorbed on the metal pipe with a magnetic. Especially suitable for the requirements of a variety of pressure flow measurement site

  The transmitter is equipped with a SD card mass storage, (Maximum storage 128 days of historical data) ,can record every moment of flow data changes, Greatly improving the safety and reliability of the cumulative traffic data collection.

  The new DCT1258 handheld ultrasonic flowmeter uses advanced modular integrated design, independent menu operation. Large LCD backlit 4-line display, Chinese interface, operation more simple and convenient

  2. Features

  Magnetic clamp installation, simple and convenient

  Compact and lightweight, easy to use

  LCD backlight, Chinese and English display

  Positive and negative flow measurement, cumulative flow

  SD card function, 2.2 million sets of data storage

  3. Apply to the fluid

  Suitable for pure liquid, In the liquid without impurities, particles, suspended matter and bubbles, and it is full pipe flow measurement

  4. Apply pipe

  Carbon steel

  stainless steel

  PVC

  Cast iron

  Copper

  Aluminium

  5.application

  ★ Water (hot water, chilled water, city water, sea water, waste water, etc.);

  ★ Sewage with small particle content;

  ★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);

  ★ Chemicals (alcohol, acids, etc.);

  ★ Plant effluent;

  ★ Beverage, liquid food;

  ★ Ultra-pure liquids;

  ★ Solvents and other liquids

  6.Specifications

Model Description
 
 
 
 
 
DCT1258
DCT1258 Handheld Ultrasonic Flowmeter
Flow Range:0~5m/s
Accuracy:±1%
Repeatability:0.2%
equipped with a SD card mass storage,maximum storage 128 days of historical data
Output:4-20mA output
Operation:64*128Dot matrix backlit LCD display
Built-in lithium working hours:After the battery is fully charged can work continuously for more than 16 hours
A Sensor Description
P CP type Portable Magnetic Sensors
Installation:outside  clamp-on
Diameter range can be measured:25mm~1200mm
Sensor cable length:5m
shell of probe: CPVC
Operating Temperature:0℃~+50℃
Aluminum rails
CH High temperature clamp-on sensor
Installation:outsideclamp-on
Diameter range can be measured:25mm~1200mm
Sensor cable length:9m
shell of probe: stainless steel .PEI
Operating Temperature:-40℃~+150℃
B Cable length
005 Standard cable length:3m
XXX Sensor cable length:Every 5 meters for a longer unit,Can be extended up to 305m.

  Wiring

  Size

  Select the measurement point

90 degree bend
T-Tee
Diffuser
Orifice
Regulating valve
Pumps
Vertical mounting

  Site selection principles

  1. Should avoid clock 6 or 12 point position, so as to avoid sediment at the bottom of the pipe or pipes upper part of the bubble, air-pocket caused by signal attenuation.

  2. Fully considering the tube wall scaling condition, as far as possible choose no scaling section measuring, can fully meet, need to think about scaling for lining in order to get better the measurement accuracy.

Accuracy0.2
UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
UCT3488D Multi-channel ultrasonic flowmeter
 
Accuracy0.5
DCT1188C multifunctional clamp-on type ultrasonic  flowmeter
DCT1188W multifunctional insertion type ultrasonic flowmeter
DCT1288i High dynamic response of portable type ultrasonic flowmeter
 
Accuracy1.0
DCT1158C Economical clamp-on type ultrasonic flowmeter
DCT1158SE Battery-powered type ultrasonic flowmeter
DCT1158W Economical insertion type ultrasonic flowmeter
DCT1258 Handheld Type Ultrasonic Flowmeter
 
Accuracy1.5
DCT1158SE Battery-powered Insertion type ultrasonic flowmeter
DCT1438K Buckle -measured type ultrasonic flowmeter
 
Heatcoldmeters
HCM1158LH Buildings dedicated type heat(cold)meters
HCM1158LH-K Central air-conditioning of buildings dedicated meter
HCM1188H Multifunctional type Ultrasonic Heat Meters
HCM1438LS Heat (cold)Meters