Flowmeter
Pressure Transmitter
Level Measurement
YTC Control Valve Accessories
HKC Automation Controls
ABB Valve Positioner
Mass Flow Controller
Doppler Current Meter
Pressure Switch
Yokogawa Flowmeter
Digital Pressure Gauge
Pressure Sources
Newsletter
for wholesale
about the latest offers and deals Subscribe today!

UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
  UCT3488 ultrasonic flowmeter is using the world's innovation PicoFly quantum time measuring technology and the resolution can be achieve 0.01 nanoseconds.
Description

  1. Product Information

    UCT3488 ultrasonic flowmeter is using the world's innovation PicoFly quantum time measuring technology and the resolution can be achieve 0.01 nanoseconds, breakthrough for the development of the measurement technology and the application of the high dynamic response ultrasonic flowmeter, The flow measurement rate is as high as 256 times per second, is a real high dynamic tracking flow changes and accurate measurement of the flowmeter.

  UCT3488 is a new kind of ultrasonic flowmeter, using new concept design ,it is suitable for the full pipe continuous measurement of liquid medium.The fully digital ultrasonic flowmeter with no moving parts, and high reliability, small amount of maintenance. The microprocessor on the instrument offers a unique digital signal coding code and related testing procedures, can provide long-term drift-free measurement.

  2. Features

  Dynamic response speed:0.004s

  Independent flow sampling rate: 256 times /s

  Time resolution: 10ps

  Cable signal attenuation constant (1MHZ):<-0.9Db/100m

  CPU+FPGA

  Off automatic compensation

  Installation verification function

  3. Apply to the fluid

  Suitable for pure liquid, In the liquid without impurities, particles, suspended matter and bubbles, and it is full pipe flow measurement

  4. Apply pipe

  Carbon steel

  stainless steel

  5.application

  ★ Water (hot water, chilled water, city water, sea water, waste water, etc.);

  ★ Sewage with small particle content;

  ★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);

  ★ Chemicals (alcohol, acids, etc.);

  ★ Plant effluent;

  ★ Beverage, liquid food;

  ★ Ultra-pure liquids;

  ★ Solvents and other liquids

  6.Specifications

Model Description
 
 
 
 
 
UCT3488
High Dynamic Response Ultrasonic Flowmeter
Installation:Wall Mount
Flow Range:0~± 7m/s
Accuracy:±0.5%
Repeatability:0.1%
Keyboard:16(4*4)Touch of a button
Display:20*2Dot matrix characters
Power supply:90~250VAC/48~63Hz/10~36VDC/12~24VAC
Case material:IP65,Aluminum
Output:OCT pulse output,Relay output,4-20mA output
Communications:RS-232/R485Communication Interface, Modbus protocol
Temperature:-10℃~60℃
Protection Rate:IP54
A I/O option
I 4-20mA output, OCT frequency output, Relay output,
RS-232 Communication Interface
E GPRS function
B Transmitter Chassis
1 Shell:IP65,Cast aluminum chassis
2 Explosion-proof enclosure, Ex dⅡBT4
3 Explosion-proof enclosure, Ex dⅡCT4
C Transducer
DN8 Installation:Pipe Segment
Operating Temperature:-40℃~+80℃
Process connection:GB flange
Pressure Rating:PN1.6MPa
Sensor cable length:9m
Material:Carbon plus anti-corrosion coating
DN15
DN25
DN40
DN50
DN65
DN80
DN100
DN150
DN200
DN250
D Sensor Material
1 Carbon
2 Stainless steel 304
E Cable length
009 Standard cable length:9m
XXX Sensor cable length:Every 5 meters for a longer unit,Can be extended up to 305m.
 Sensor Size Chart
Caliber
DN(mm)
Dimensions(mm)
L W H
25 400 120 180
40 450 135 200
50 500 150 210
65 400 230 165
80 400 245 190
100 400 265 215
150 450 315 280
200 550 365 335
250 600 415 405
Transmitter Size

Sensor Size

Installation diagram

90 degree bend
        
T-Tee
                    
Diffuser
                        
Orifice
                  
Regulating valve
                       
Pumps
                   
Vertical mounting
                        
Site selection principles

  1. Should avoid clock 6 or 12 point position, so as to avoid sediment at the bottom of the pipe or pipes upper part of the bubble, air-pocket caused by signal attenuation.

  2. Fully considering the tube wall scaling condition, as far as possible choose no scaling section measuring, can fully meet, need to think about scaling for lining in order to get better the measurement accuracy.

Accuracy0.2
UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
UCT3488D Multi-channel ultrasonic flowmeter
 
Accuracy0.5
DCT1188C multifunctional clamp-on type ultrasonic  flowmeter
DCT1188W multifunctional insertion type ultrasonic flowmeter
DCT1288i High dynamic response of portable type ultrasonic flowmeter
 
Accuracy1.0
DCT1158C Economical clamp-on type ultrasonic flowmeter
DCT1158SE Battery-powered type ultrasonic flowmeter
DCT1158W Economical insertion type ultrasonic flowmeter
DCT1258 Handheld Type Ultrasonic Flowmeter
 
Accuracy1.5
DCT1158SE Battery-powered Insertion type ultrasonic flowmeter
DCT1438K Buckle -measured type ultrasonic flowmeter
 
Heatcoldmeters
HCM1158LH Buildings dedicated type heat(cold)meters
HCM1158LH-K Central air-conditioning of buildings dedicated meter
HCM1188H Multifunctional type Ultrasonic Heat Meters
HCM1438LS Heat (cold)Meters

saleMan 1:
saleMan 2:
saleMan 3:
saleMan 4: