1. Product Information
UCT3488D multi-channel ultrasonic flowmeter is a wide range of applications, high accuracy, high reliability, multi-function products, suitable for large-caliber trade metered delivery of the occasion, It uses the velocity distribution and the cross-sectional area partition integral calculation flow way, The error caused by the flow instability is minimized, the measured velocity distributions that best reflects the state of the medium flow in the pipeline, effectively improve the accuracy of measurement, suitable for the occasion of short section before and after, Both pipe sections and the scene installation is very simple, Online installation does not require users to suspend production, therefore preferred customers transform upgrade.
2. Features
The positive and negative flow, cumulative flow measurement, and two-way flowmeter measurement
High measurement accuracy
Short straight pipe upstream and downstream
Suitable for large diameter pipe measurement
Sensor redundancy technology
Online installation with pressure
No pressure loss
RS-485Communication interface, Modbus protocol
3. Apply to the fluid
Suitable for pure liquid, In the liquid without impurities, particles, suspended matter and bubbles,
wide range of applications, guide liquid can be measured.
4. Apply pipe
Carbon steel
stainless steel
5.application
★ Water (hot water, chilled water, city water, sea water, waste water, etc.);
★ Sewage with small particle content;
★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);
★ Chemicals (alcohol, acids, etc.);
★ Plant effluent;
★ Beverage, liquid food;
★ Ultra-pure liquids;
★ Solvents and other liquids
6. Specifications
Model | Description |
UCT3488 |
UCT3488 Multi-channel ultrasonic flowmeter Installation:Wall Mount Flow Range:0~± 7m/s Operation:Keyboard Repeatability:0.04% or 0.1% Accuracy:0.2 or 0.5 Display:20*2characters Power supply:220VAC±10%@48~63Hz,Optional 24VDC Case material:Aluminum Protection Level: IP65 Output:OCT pulse output,Relay output,4-20mAoutput Communications:RS-485Communication interface, Modbus protocol |
A | I/O option |
1 | Standard:4-20mA output, OCT pulse output, Relay output, |
2 | GPRS function |
B | Transmitter Case |
1 | Outer casing:IP65,Cast aluminum case |
2 | Explosion-proof enclosure, Ex dⅡBT4 |
3 | Explosion-proof enclosure, Ex dⅡCT4 |
4 | Explosion-proof enclosure, Ex dⅡBT6 |
5 | Explosion-proof enclosure, Ex dⅡCT6 |
C | Transducer |
W210 |
Normal temperature plug-in, Pressure Rating:PN1.6MPa Protection Level: IP68 Temperature caliber:DN50~DN1200 Temperature:-40℃~+80℃ |
DN50~DN600 |
Normal tube stage, Pressure Rating:PN1.6MPa Protection Level: IP68 Temperature:-20℃~+80℃ |
D | Number of channels |
1 | 2 channel (≥DN100) |
2 | 3 channel (≥DN150) |
3 | 4 channel (≥DN300)) |
4 | 5 channel (≥DN400) |
5 | 6 channel (≥DN500) |
E | Accuracy Level |
1 | 0.2 |
2 | 0.5 |
channel | 2 | 3 | 4 | 5 | 6 | |
caliber | ≥DN100 | ≥DN200 | ≥DN300 | ≥DN400 | ≥DN500 | |
Flow speed range | 0.05-7m/s | 0.05-7m/s | 0.05-7m/s | 0.05-7m/s | 0.05-7m/s | |
Accuracy level | 0.5/0.2 | |||||
Repeatability | 0.1% or 0.04% | |||||
Pipe-stage sensor | ||||||
Pressure Rating | PN1.6MPa | |||||
Temperature | -20℃~+80℃ | |||||
Protection level | IP68 | |||||
Explosion level | Ex dⅡBT4/CT4/BT6/CT6 | |||||
Flange Standard | GB/T 9112-2000 | |||||
Probe Material | Stainless steel, PEI,Teflon,Carbon steel base | |||||
Cable length | 9m | |||||
Transmitter | ||||||
Display | 20*2Dot matrix characters | |||||
Operation | Touch of a button | |||||
Analog Output | One-way 4-20mA | |||||
Pulse output | One-way 0-5kHz | |||||
Relay output, | One-way 250VAC@1A | |||||
Power supply | 220VAC, 50-60Hz | |||||
Power Consumption | 20W | |||||
Dimensions | 230(w) *280(H)*110(D), (mm) | |||||
Cable outlet Standard | 5-M20*1.5 |
Caliber DN(mm) |
Installation length (mm) |
Height (mm) |
Pressure Rating |
100 | 250 | 220 | 1.6MPa |
150 | 300 | 285 | |
200 | 350 | 340 | |
250 | 400 | 405 | |
300 | 500 | 460 | |
350 | 500 | 520 | |
400 | 600 | 580 | |
450 | 600 | 640 | |
500 | 600 | 715 | |
600 | 800 | 840 |
90 degree bend |
T-Tee |
Diffuser |
Orifice |
Regulating valve |
Pumps |
Vertical mounting |
Site selection principles
1.Measurement point should be chosen from the 5 times the diameter of the upstream and the 3 times the diameter of the downstream, in this range there is no any valves, elbows, reducers and other interference flow field
2. If the pump , T-tee ,valve, orifice, pipe or other causes of rotating flow device before the measurement point, upstream pipe section requires longer
Accuracy:0.2
UCT3488 Series High Dynamic Response Ultrasonic Flowmeter
UCT3488D Multi-channel ultrasonic flowmeter
Accuracy:0.5
DCT1188C multifunctional clamp-on type ultrasonic flowmeter
DCT1188W multifunctional insertion type ultrasonic flowmeter
DCT1288i High dynamic response of portable type ultrasonic flowmeter
Accuracy:1.0
DCT1158C Economical clamp-on type ultrasonic flowmeter
DCT1158SE Battery-powered type ultrasonic flowmeter
DCT1158W Economical insertion type ultrasonic flowmeter
DCT1258 Handheld Type Ultrasonic Flowmeter
Accuracy:1.5
DCT1158SE Battery-powered Insertion type ultrasonic flowmeter
DCT1438K Buckle -measured type ultrasonic flowmeter
Heat(cold)meters
HCM1158LH Buildings dedicated type heat(cold)meters
HCM1158LH-K Central air-conditioning of buildings dedicated meter
HCM1188H Multifunctional type Ultrasonic Heat Meters
HCM1438LS Heat (cold)Meters