1. product introduction
Ultrasonic flow module/RTU is widely used in all kinds of liquid for long time measurement, neither need broken tube nor block installation. The main unit uses guide installation, and the sensor was installed in the measurement pipelines. The main unit and sensor connected by the ultrasonic flow meter’s special power cable, not only can complete the flow measurement, but also complete the measurement of the quantity of the heat. This series are widely used to meausre the form a complete set of system integration, water resources, energy saving, water supply and drainage, heating network monitoring projects such as flow rate, heat metering.
2. the features
High accuracy: accuracy can reached to 1 %.
Wide measuring range: Several types transducer for selection, pipe size from DN15mm to DN6000mm
High reliability: Low voltage, pulse transmission circuit, high measurement accuracy, Improve the service life and reliability.
Strong anti-interference ability: Adopt double balanced differential signal transmitting and receiving circuit to resist inverter, television tower, high tension line
interference effectively.
Powerful Functions: Current output: 4-20mA, one channel, can be used for flow/heat transmitter;
OCT output: two channels, can be used for flow /heat switch;
Current input: 4-20mA, three channels, can be used for data collector;
Tri-wire resistance signal input (PT100): two channels, can be used for calorimeter.
Far transmission distance: Connecting module and secondary meter through RS-485 interface, transmission distance up to 1000m.
Support the heat measurement: measuring the heat through connect with the temperature sensor.
3. Measurement of figure
Flow measurement | The heat/cold quantity measurement | Features |
Clamp-on transducer | ||
Installation without broken tube or flow, no pressure loss. And easy to install. Match with clip temperature sensor that can measure the temperature of the outer of pipeline, which realize the heat quantity measurement. |
||
insertion | ||
Installation without broken tube or flow, no pressure loss. Long-term stability and reliable operation. Adapt to inserted temperature sensor so that realize the measurement of the heat quatity. |
||
prover section | ||
Installation without broken tube or flow, no pressure loss. And easy to install. Match with inserted temperature sensor that can measure the temperature of the outer of pipeline, which realize the heat quantity measurement. |
category | Pictures | Specifications | Model | Diameter | Temperature range | Size | |
Clamp-on transducer | small size | TS-2 | DN15~DN100 | -30~90℃ | 45×25×32mm | ||
Medium size | TM-1 | DN50~DN700 | -30~90℃ | 64×39×44mm | |||
Large size | TL-1 | DN300~DN6000 | -30~90℃ | 97×54×53mm | |||
High temperature clamp-on transducer | High temperature small size | TS-2-HT | DN15~DN100 | -30~160℃ | 45×25×32mm | ||
High temperature medium size | TM-1-HT | DN50~DN700 | -30~160℃ | 64×39×44mm | |||
High temperature large size | TL-1-HT | DN300~DN6000 | -30~160℃ | 97×54×53mm | |||
Insert-type | Standard size | TC-1 | DN80~DN6000 | -30~160℃ | 190×80×55mm | ||
Extended type | TC-2 | DN80~DN6000 | -30~160℃ | 335×80×55mm | |||
Prover section | Prover section of πtype | G3 | DN15~DN25 | -30~160℃ |
304 steel stainless Threaded connections |
The detailed reference to the pipe section of sensor specification table | |
Standard prover section | G2 | DN32~DN40 | -30~160℃ |
Carbon steel material Threaded connections |
|||
Standard prover section | G1 | DN50~DN6000 | -30~160℃ |
Carbon steel material Flange connections |
Pictures | Type | Model | Measurement range | Temperature range | Installation requirements | Accuracy |
Three wire system PT100 Clamp-on temperature transducer |
CT-1 | >DN50 | -40~160℃ | without broken tube |
100℃±0. 8℃ The temperature difference after exact match is≤0. 1℃ |
|
Three wire system PT100 Inserted temperature sensor |
TCT- 1 | >DN50 | -40~160℃ | broken tube | ||
Three wire system PT100 Inserted Temperature transducer with pressure installation |
PCT- 1 | >DN50 | -40~160℃ | without broken tube | ||
Small diameter with three wire system PT100 Inserted temperature sensor |
SCT-1 | <DN50 | -40~160℃ | broken tube |
Category | Performance and parameters | ||
Main unit | Principle | Time different principle, 4 bytes IEEE754 floating point arithmetic | |
Accuracy | Flow: be superior to ±1% | ||
Operate | 4 key touch the keyboard | ||
Signal output
|
1 way output 4 ~20mA, impedance 0~1K, accuracy 0.1% | ||
1 way OCT pulse output(pulse width is 6~1000ms,the default is 200ms) | |||
1 way relay output | |||
Signal input | 3 way input 4~20mA, accuracy is 0.1%, can be collected, such as the temperature ,pressure, liquid level signal. | ||
It can connect with 3-wire system PT100, to measure the heat quantity | |||
Data interface | Isolation of RS485 serial interface, can through the PC to upgrade Flowmeter. Supported MODBUS. | ||
Special cable | Custom twisted-pair, generally limited to 50 meters; Choose RS485 communications, the transmission distance can reach more than kilometers | ||
Situation of the pipeline | Pipe material | Steel, aluminum, stainless steel, cast iron, copper, PVC, FRP etc. All quality of pipeline,allows for the lining. | |
Internal diameter of pipe | 15~6000mm | ||
Straight pipe | To meet the sensor installation point, 10 D, downstream 5 D, 30 D to the pump discharge for pipe diameter (D) | ||
Measurement media | Items | Water, sea water, industrial wastewater, acid alkali, alcohol, beer, various oil etc all kinds can conduction a homogeneous liquid of ultrasonic. | |
Temperature | Temperature:-30~160℃ | ||
Turbidity | 10000ppm And the bubble content is small | ||
Flow rate | 0~±10m/s | ||
Work environment | Temperature | Host :-20~60℃;flow sensor:-30~160℃ | |
Humidity | Host :85% RH, flow sensor: it can be worked in the water, depth of water≤2m (NOTE: After the glue) | ||
Power | DC8~36V or AC85~264V(optional) | ||
Power consumption go | 1.5W |
Flow sensor | TS-2 | Small size clamp-on transducer | Pipe | 0 | Carbon steel | Temperature sensor | N | No temperature measurement |
TM-1 | Medium size clamp-on transducer | 1 | Steel stainless | CT-1 | Clamp-on temperature transducer | |||
TL-1 | large size clamp-on transducer | 2 | Cast iron | TCT-1 | Temperature insertion transducer | |||
TS-2-HT |
Small size High temperature Clamp-on transducer |
3 | Glass fiber reinforced plastic | PCT-1 | Inserted temperature sensor with pressure installation | |||
TM-1-HT |
Medium size High temperature Clamp-on transducer |
4 | PVC | SCT-1 | Small temperature transducer | |||
TL-1-HT |
Large size High temperature Clamp-on transducer |
5 | Cement | |||||
TC-1 | Standard insertion type | 6 | Other | |||||
TC-2 | Extended insertion | |||||||
G | Pipe section | |||||||
Examples | TUF -2000M -TM -1 -DN300 -0 -1 .6MPa -10m -PCT-1 | |||||||
Explanation | Fixed one-piece ultrasonic Flowmeter,Medium-sized clamp type sensor, diameter is DN300, Carbon steel material, nominal pressure 1. 6 mpa, between the host and sensor cable length is 10 meters, have the function of heat measurement, matching with pressure insertion type temperature sensor installation. |
Target Flowmeter/Functional Unified Fixed Ultrasonic Flowmeter/Handheld Ultrasonic Flowmeter/ Ultrasonic Flow Module/Portable Ultrasonic Flowmeter/Separate Fixed Ultrasonic Flowmeter/Insertion type Electromagnetic Flowmeter/ Battery powered Electromagnetic Flowmeter/ Remote Type electromagnetic Flowmeter/ TYLD Flanged Electromagnetic Flowmeter/Clamped Electromagnetic Flowmeter/ Metal Tube Float Flowmeter/ Verabar of the Flowmeter/ Insertion Vortex Street Meter/ Integrated Vortex Flowmeter with Temperature & Pressure Compensation/ Intelligent Vortex Flowmeter/ Gas Turbine Flowmeter/ Liquid Turbine Flowmeter/Thermal Gas Mass Flowmeter/ Coriolis Mass Flowmeter/LFX rotor steam Flowmeter/ LUXB liquid precession vortex Flowmeter/ Cross section Flowmeter/ FP-64B balanced dual-chamber container/ LG series throttling device/Integral differential pressure flowmeter/LC Oval gear flowmeter/V Cone Flowmeter/LGBA Annubar Flowmeter/ LGBD Delta Flowmeter/3151 on-line densimeter