Liquid Turbine Flowmeter
  LWGY series turbine flow sensor (the follows call it sensor) is based on the principle of moment balance,so belongs to speed type flow meter.
Description

1. introduction

  LWGY series turbine flow sensor (the follows call it sensor) is based on the principle of moment balance, so belongs to speed type flow meter. The sensor has the advantages of simple structure, light and handy, high accuracy, good repeatable, responsive and easy to install and maintenance. It is widely used in industry of Petroleum, chemical industry, metallurgy, water supply, paper making, etc. Ordinary the sensor working with indication instruments together. It is appropriate for measuring pipeline’s impurities of liquid, which do not corrosion effect with the steel stainless 1Cr18Ni9Ti、2Cr13, 2Cr13,
corundum and Al2O3 hard alloy. If used with special function display instruments, also Can be quantitatively controlled, Excessive alarm etc. you can chose the explosion-proof type, because it can used in the explosion dangerous environment.

  This sensor apply for working in the Viscosity is less than 5 x 10-6 m2 / s of medium. If over this value, you should make a solid liquid calibration of sensor after use. If users need to special kind of sensor, you can negotiate orders, if sensor explosion-proof type, in order to illustrate.

2. Features

  1. low pressure loss.

  2. Have high resistance to electromagnetic interference and vibration resistance, performance reliable working life is long.

  3. To adopt advanced technology of ultra-low power consumption single chip microcomputer. The whole machine function is strong, low power consumption, superior performance. With nonlinear precision compensation function of wisdom, the accuracy of correction formula is better than that of plus or minus 0.02%.

  4. Instrument coefficient can be set up by the button online, and can be displayed on the LCD screen, LCD screen clear intuitive, high reliability.

3. Operation and adjustment

  ◆To keep liquid clean and no fiber and impurity.

  ◆Please open valve slowly and fill the sensor gradually. High water hamper to the empty sensor was prohibited.

  ◆Normally sensor maintenance period is six months. During cleaning of sensor, please pay attention not to damage measurement cavity parts,especially the turbine. Before assembly, please pay attention to the relationship between the turbine and flow-guider.

  ◆For storage, please clean the liquid inside the sensor, and cover 2 ends of the sensor againstimpurity entering the sensor. Please keep the sensor in dry and clean place

  ◆For equipped filter, please clean it periodically. When it’s not used, please clean and store it just as to sensor.

  ◆Sensor's transmission cable can be laid overhead or underground (please put the cable into metal pipe if it’s buried underground.)

  ◆Before sensors installed, please connect electrically the sensor to indicator to see whether indicator shows flow when user rotates the turbine. If no flow displays on indicator, please check the relevant part to kill trouble before installation.

4. Specifications

Type and marks Specification
Type
LWGY □□□  
LWGY Basically ,+12V power supply,pulse output,
high level≥8V
Low level≤0.8V
LWGYA 4~20mA two-wire system current output, far distance transmitter type
LWGYB Batterytype with display
LWGYC display /4~20mAtwo-wire system current output
Diameter 4 4mm,Ordinary turbine flow range is 0.04~0.25m3/h
Wide-range turbine is 0.04~0.4m3/h
6 6mm,Ordinary turbine flow range is  0.1~0.6m3/h
Wide-range turbine is 0.06~0.6m3/h
10 10mm,Ordinary turbine flow range is 0.2~1.2m3/h
Wide-range turbine is 0.15~1.5m3/h
15 15mm,Ordinary turbine flow range is 0.6~6m3/h
Wide-range turbine is 0.4~8m3/h
25 25mm,Ordinary turbine flow range is 1~10m3/h
Wide-range turbine is 0.5~10m3/h
40 40mm,Ordinary turbine flow range is 2~20m3/h
Wide-range turbine is 1~20m3/h
50 50mm,Ordinary turbine flow range is 4~40m3/h
Wide-range turbine is 2~40m3/h
80 80mm,Ordinary turbine flow range is 10~100m3/h
Wide-range turbine is 5~100m3/h
100 100mm,Ordinary turbine flow range is 20~200m3/h
Wide-range turbine is 10~200m3/h
150 150mm,Ordinary turbine flow range is 30~300m3/h
Wide-range turbine is 15~300m3/h
200 200mm,Ordinary turbine flow range is 80~800m3/h
Wide-range turbine is 40~800m3/h
Explosion-proof No mark is the unexplosion-proof type
B Explosion-proof type
Accuracy grade A 0.5
B 1
Turbine type A Widely range turbine
B Ordinary turbine
 Installation, use and adjustment

  The installation type of sensors can be thread or flange based on sensor size. Please view

  Figure 1, Figure 2, Figure 3, for installation. See table 2 for installation size.








Target Flowmeter/Functional Unified Fixed Ultrasonic Flowmeter/Handheld Ultrasonic Flowmeter/ Ultrasonic Flow Module/Portable Ultrasonic Flowmeter/Separate Fixed Ultrasonic Flowmeter/Insertion type Electromagnetic Flowmeter/ Battery powered Electromagnetic Flowmeter/ Remote Type electromagnetic Flowmeter/ TYLD Flanged Electromagnetic Flowmeter/Clamped Electromagnetic Flowmeter/ Metal Tube Float Flowmeter/ Verabar of the Flowmeter/ Insertion Vortex Street Meter/ Integrated Vortex Flowmeter with Temperature & Pressure Compensation/ Intelligent Vortex Flowmeter/ Gas Turbine Flowmeter/ Liquid Turbine Flowmeter/Thermal Gas Mass Flowmeter/ Coriolis Mass Flowmeter/LFX rotor steam Flowmeter/ LUXB liquid precession vortex Flowmeter/ Cross section Flowmeter/ FP-64B balanced dual-chamber container/ LG series throttling device/Integral differential pressure flowmeter/LC Oval gear flowmeter/V Cone Flowmeter/LGBA Annubar Flowmeter/ LGBD Delta Flowmeter/3151 on-line densimeter
 



 
 