1. Product introduction
LGBD Delta Flowmeter is a kind of uniform tube Flowmeter, it was belongs to the principle of differential pressure type. Plug-in installation method designed a flow sensor. Delta the flowmeter pressure hole through two rows of lead pipe from the top down (from left to right) of the different pressure (flow) formed after the average differential pressure, which can calculate the mass flow rate or volumetric flow.
2. Range of application
1、 nominal diameter:25mm≤DN≤6000mm;
2、 nominal pressure:PN≤25MPa;
3、 medium temperature:t≤650℃;
4、 accuracy grade:0.5,1,1.5.
3. model selection
Project | Cede | Instruction | ||||||
LGB | Uniform tube Flowmeter | |||||||
Sensor items | D | Delta flowmeter | ||||||
W | Power flowmter | |||||||
A | Aniu Flowmeter | |||||||
Medium | Y | Liquid | ||||||
Q | Gas | |||||||
Z | Steam | |||||||
Fluid temperature | 2 | <200℃ | ||||||
5 | <500℃ | |||||||
Fluid pressure | 1 | ≤1.6MPA | ||||||
2 | ≤4.0MPA | |||||||
3 | ≤6.3MPA | |||||||
4 | ≤10.0MPA | |||||||
5 | ≤25.0MPA | |||||||
Accuracy | 1 | 1.0 | ||||||
2 | 1.5 | |||||||
3 | 2.5 | |||||||
Connection | 1 | Threaded connection | ||||||
2 | Flange connections | |||||||
Diameter | DN | Figuring (nominal diameter) | ||||||
Attachment(optional) | F | With removable ball valve installation | ||||||
J | With globe valve | |||||||
L | With condenser pipe | |||||||
S | With three valve group | |||||||
CB | Differential pressure transmitter | |||||||
XJ | Flow totalizer | |||||||
BC | Temperature compensation with the temperature and pressure sensor |