1. The product description
Adopting metal sensor With simulation, HART, PROFIBUS PA or FF fieldbus
Advantages
High repeatability and long-term stability
High accuracy: ±0.15%,Platinum edition: ±0.075%
Range than 100:1
· modular design and used to differential /static and gauge pressure. (Deltabar M - Deltapilot M - Cerabar M), ex:
- Can change the display unit
- universal electrical modular
· easy to debug,Don't need to use other operating tools
· the menu guide operate
– through site display modular
– through 4 ... 20 mA HART
– though PROFIBUS PA
– though FF fieldbus
2. Application feilds
Cerabar M pressure transmitter can solve the measurement problems as follows:
measuring the absolute pressure and gauge pressure gas/steam or liquid in all kinds of process control field.
Measuring the level, volume and mass of liquid.
The process temperature can reached to 125°C (302°F)
Have many certifications, that can satisfied with all required applications in the word.
3. the technology information
Measurement principle | Hydrostatic | |
Characteristic / Application | Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm | |
Supply /Communication |
4 ..20mA HART: 11,5...45V DC Ex ia: 11,5...30V DC PROFIBUS PA FOUNDATION Fieldbus |
|
Accuracy |
0,15% Platinum 0,075% |
|
Long term stability | 0,1% of URL/year | |
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
|
Process temperature |
-40°C...125°C (-40°F...275°F) |
|
Process pressure absolute / max. overpressure limit | 600bar (9000psi) | |
Pressure measuring range |
1bar...400bar (15psi...6000psi) |
|
Main wetted parts | 316L | |
Process connection |
Threads Flanges (DIN, ANSI, JIS) Hygienic connections Tri-Clamp ISO2852 |
|
Max. measurement distance | 4000m (13.123ft) H2O | |
Output |
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
|
Certificates / Approvals |
ATEX CSA FM IECEx TIIS NACE SIL EHEDG, 3A,FDA inspection certificates |
|
Options | local display | |
Application limits |
Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
Measurement principle | Hydrostatic | |
Characteristic | Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm | |
Supply /Communication |
4 ..20mA HART: 11,5...45V DC Ex ia: 11,5...30V DC PROFIBUS PA/ FOUNDATION Fieldbus: 9..32 V DC (Non Ex) |
|
Accuracy |
Standard 0,15% Platinum 0,075% |
|
Long term stability | 0,1% of URL/year | |
Process temperature |
-40°C...130°C (-40°F...266°F 150°C for 1h (302°F for 1h) |
|
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
|
Measuring range |
400mbar...400bar (15psi...6000psi) |
|
Max. overpressure limit | 600bar (9000psi) | |
Process connection |
Thread: G1/2...G2, MNPT1/2...MNPT2 Flange: DN25...DN80, ASME 1 1/2"...4", |
|
Hygienic |
Tri-Clamp DIN11851 NEUMO Varivent N SMS DRD |
|
Output |
4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
|
Certificates / Approvals |
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI SIL EN10204-3.1 NACE 3A, EHEDG CoC ASME-BPE Marine |
|
Options |
Display PWIS free |
|
Specialities | SIL 2 according to IEC 61508 |