1. product description
Used for pressure transducer type health situation It can measure absolute and gauge pressure,the highest is 40bar,Use metal diaphragm, flush installation.
Advantages
The integration of the pressure transmitter,The use of advanced structural design:
1. Use metal diaphragm, flush installation
2. 3 a standard health type design.
3. As much as 4 times of resistance to overload ability,High and long-term operation stability
4. An optional 3.1 B testing certificate
5. The material of contact process parts is stainless steel 316L,The surface roughness is Ra ≤ 0.8 μm.
2. application fields
The Cerabar T PMP 135 Applicable to the health type pressure transducer,Such as food processing and pharmaceutical industry. Used to measure absolute and gauge pressure of the gas, steam , liquid and dust.
1. The measurement range can reached to 40 bar or 500 psi
2. Electrical modular
- simulated 4...20 mA output
- switch output
- dangerous area use certificate
2. Information
Measurement principle | Absolute and gauge pressure | |
Characteristic | Cost-effective pressure transducer with piezoresistive sensor, and flush mounted metallic diaphragm for hygienic applications | |
Supply / Communication |
Analogue output: 12...30V DC, Switch output: 18...32V DC |
|
Accuracy | 0,5% | |
Long term stability | 0,15% of URL/year | |
Process temperature |
-25°C...100°C (-13°F...212°F) 135°C for 1h (275°F for 1h) |
|
Ambient temperature |
-25°C...70°C (-13°F...758°F) |
|
Measuring range |
1bar...40bar (15psi...600psi) |
|
Max. overpressure limit | 160bar (2320psi) | |
Process connection |
Threads Tri-Clamp ISO2852 Hygienic connections |
|
Output |
4...20mA analogue PNP switch |
|
Certificates / Approvals |
ATEX SIL 3A EN10204-3.1 |
|
Options | calibration protocol | |
Specialities | switch output |