1. Description
Process pressure For absolute pressure and table security measurement and monitoring of pressure switch
Advantages
A integration of pressure switch,Using the most advanced technology:
· Built-in switch electronic plug-in,to monitoring and control process of distributed and the economy
· Modular construction, easy To facilitate rapid and flexible system integration
· High repeatability and long-term stability
· The LED and digital display to proceed the function testing and information display on the sense
· Ceraphire® sensor’s diaphragm : Corrosion resistance, wear resistance, resistance to overload ability
· High accuracy,short response time,small measurement range
· To operate and visual display through the computer and ReadWin® 2000 software.
· The upper shell can rotate 310°,Convenient to read Omni directional measured value
· Conform to DESINA
· 3A authentication
2. application fields
For monitoring gas, steam, liquid and dust of the pressure and the pressure of gage pressure switch Ceraphant T PTP31 − Use a metal sensor diaphragm
Precise measurement range:vacuum - 400bar/6000 psi.
This type can be used in the health situation
Electronic plug-in type
- 1 road PNP switch output
- 2road PNP switch output
- PNP Switch output with simulation 4...20 mA output
3. Information
Measurement principle | Pressure switch | |
Characteristic | Intelligent pressure switch with piezoresistive sensor, longterm stable and overload resistant | |
Supply / Communication | 12...30VDC | |
Accuracy | 0,5% | |
Long term stability | 0,15% of URL/year | |
Process temperature |
-40°C...100°C (-40°F...212°F) |
|
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
|
Measuring range |
1bar...400bar (15psi...6000psi) |
|
Max. overpressure limit | 600bar (9000psi) | |
Process connection | Threads | |
Output |
1x PNP switch 2x PNP switch 1x PNP switch + 4...20mA analogue |
|
Certificates / Approvals |
CULUS EN10204-3.1 |
|
Options | calibration protocol | |
Specialities |
Digital display Robust SS-housing with Ra < 0,8 micron |
|
Hint | Please check also temperature swith Thermophant T with the identical look and feel of the housing, electronics and software. |