1. Production description
Deltabar S with front flush ceramic measuring diaphragm. Overlod-resistant with function-monitoring. Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus.
2. Areas of application
The Deltabar S differential pressure transmitter is used for the following measuring tasks:
1. Level, volume or mass measurement in liquids
2. Differential pressure monitoring, e.g. of filters and pumps
3. International usage thanks to wide range of approvals
Application arear
1. Very good reproducibility and long-term stability
2. High reference accuracy: up to 0.075%,
as PLATINUM version: 0.05%
3. Turn down 100:1, higher on request
4. Used for flow or differential pressure monitoring up to SIL 2,
certified according to IEC 61508 by TüV SüD
5. meets PED (Pressure Equipment Directive)
6. HistoROM®/M-DAT memory module
7. Function-monitored from the measuring cell to the electronics
8. Continuous modularity for differential pressure and pressure
(Deltabar S - Cerabar S), e.g.
- replaceable display
- universal electronics
9. Quick commissioning thanks to quick setup menu
10. Easy and safe menu-guided operation on-site, via 4...20 mA with HART,
PROFIBUS PA or FOUNDATION Fieldbus
Extensive diagnostic functions
Technical information
Reference accuracy: |
up to 0.075% of the set span, PLATINUM version: 0.05% of the set span |
Measuring range: | from -100...+100 mbar to -3...+3 bar |
Overload: | on one side: max. 100 bar |
Process temperature: | -20...+85°C (-4...+185°F) |
Ambient temperature: | -20...+85°C (-4...+185°F) |
Certificates: | ATEX, CSA, FM, NEPSI, IECEx |
Specialities: |
- Abrivasion-resistant and corrosion-resistant - No diaphragm-seal temperature effects - Metal-free measurement possible with ECTFE-coated process connection |