1. product description
Static pressure level measuring system Adopted CONTITETM measurement unit sensor Resistance to condensation,long-term and high stabilty,HART, PROFIBUS PA or FF fieldbus
Advantages
The best repeatable and long-term stability
Seal welding CONTITETM measurement unit:
- Condensation resistance, climate protection ability
- High precision measurement: ±0.1%
- Small temperature influence
Process monitoring security can reach to SIL3, By TuV SuD according to IEC 61508 standard certification
HistoROM®/M-DAT Storage module
From the measuring element to the electronic module has function monitoring
Modular design,it can be exchanged with measuring instrument of differential pressure ,static pressure and gauge pressure. (Deltabar S, Deltapilot S, Cerabar S)
- Pressure and differential pressure electronic module
Fast easy set menu for configuration Settings
The heuristic operation menu
A wide range of self-diagnosis functions
2. application fields
Static pressure sensor can be used to solve the measurement problem:
1. Process industries such as pharmaceutical, food industry, a variety of liquid and paste in the medium of static pressure measurement
2. liquid level, volume or mass measurements
3. technology information
Measurement principle | Hydrostatic | |
Characteristic / Application |
Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell: - hermetically welded - absolute condensation tight - climate-resitant - long-term stable - Lowest temperature influences Compact version Modular Deviceplatform |
|
Supply / Communication |
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
|
Accuracy |
Standard 0,1% Optional 0,075% |
|
Long term stability | 0,05% of URL/year | |
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
|
Process temperature |
-10°C...100°C (14°F...212°F) |
|
Process pressure absolute / max. overpressure limit | 40 bar (600 psi) | |
Pressure measuring range |
100mbar...10bar (1.5psi...150psi) |
|
Main wetted parts |
Alloy C 316L |
|
Process connection |
Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
|
Process connection hygienic |
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
|
Max. measurement distance | 100m (328ft) H2O | |
Output |
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
|
Certificates / Approvals |
ATEX, FM, CSA C/US, IEC Ex, TIIS, NEPSI Overfill prevention WHG SIL EN10204-3.1 3A, EHEDG CoC ASME-BPE |
|
Options |
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
|
Specialities | Diagnostic functions | |
Application limits |
Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure |
Measurement principle | Hydrostatic | |
Characteristic |
Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell: - hermetically welded - absolute condensation tight - climate-resitant - long-term stable - Lowest temperature influences Compact version Modular Deviceplatform |
|
Supply / Communication |
4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
|
Accuracy |
Standard 0,1% Optional 0,075% |
|
Long term stability | 0,05% of URL/year | |
Process temperature |
-10°C...100°C (14°F...212°F) |
|
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
|
Measuring range |
100mbar...10bar (1.5psi...150psi) |
|
Max. overpressure limit | 40 bar (600 psi) | |
Process connection |
Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
|
Hygienic |
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
|
Output |
4 ... 20 mA HART PROFIBUS PA FOUNDATIONn Fieldbus |
|
Certificates / Approvals |
ATEX, FM, CSA C/US, IEC Ex, TIIS, NEPSI Overfill prevention WHG SIL EN10204-3.1 3A, EHEDG CoC ASME-BPE |
|
Options |
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
|
Specialities | Gold-rhodium coated membrane |