E+H Deltapilot S FMB70
  Static pressure level measuring system Adopted CONTITETM measurement unit sensor Resistance to condensation,long-term and high stabilty,HART, PROFIBUS PA or FF fieldbus
Description

1. product description

  Static pressure level measuring system Adopted CONTITETM measurement unit sensor Resistance to condensation,long-term and high stabilty,HART, PROFIBUS PA or FF fieldbus

  Advantages

  The best repeatable and long-term stability

  Seal welding CONTITETM measurement unit:

  - Condensation resistance, climate protection ability

  - High precision measurement: ±0.1%

  - Small temperature influence

  Process monitoring security can reach to SIL3, By TuV SuD according to IEC 61508 standard certification

  HistoROM®/M-DAT Storage module

  From the measuring element to the electronic module has function monitoring

  Modular design,it can be exchanged with measuring instrument of differential pressure ,static pressure and gauge pressure. (Deltabar S, Deltapilot S, Cerabar S)

  - Pressure and differential pressure electronic module

  Fast easy set menu for configuration Settings

  The heuristic operation menu

  A wide range of self-diagnosis functions

2. application fields

  Static pressure sensor can be used to solve the measurement problem:

  1. Process industries such as pharmaceutical, food industry, a variety of liquid and paste in the medium of static pressure measurement

  2. liquid level, volume or mass measurements

3. technology information

Measurement principle Hydrostatic
Characteristic / Application Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Compact version Modular Deviceplatform
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0,1%
Optional 0,075%
Long term stability 0,05% of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -10°C...100°C
(14°F...212°F)
Process pressure absolute / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100mbar...10bar
(1.5psi...150psi)
Main wetted parts Alloy C
316L
Process connection Thread:
G1 1/2, MNPT1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K
Process connection hygienic Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Max. measurement distance 100m (328ft) H2O
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, NEPSI
Overfill prevention WHG
SIL
EN10204-3.1
3A, EHEDG
CoC ASME-BPE
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Specialities Diagnostic functions
Application limits Measuring cell: Contite, condensate-proof, watertight, metal welded
If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure
 
Measurement principle Hydrostatic
Characteristic Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Compact version Modular Deviceplatform
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0,1%
Optional 0,075%
Long term stability 0,05% of URL/year
Process temperature -10°C...100°C
(14°F...212°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring range 100mbar...10bar
(1.5psi...150psi)
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K
Hygienic Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Output 4 ... 20 mA HART
PROFIBUS PA
FOUNDATIONn Fieldbus
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, NEPSI
Overfill prevention WHG
SIL
EN10204-3.1
3A, EHEDG
CoC ASME-BPE
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Specialities Gold-rhodium coated membrane



E+H Deltabar FMD72/ E+H Deltabar M PMD55/ E+H Deltabar S FMD76/ E+H Deltabar S FMD77/E+H Deltabar S FMD78/ E+H Deltabar S PMD70/ E+H Deltabar S PMD75/
E+H Deltapilot M FMB50/ E+H Deltapilot M FMB51/ E+H Deltapilot M FMB52/ E+H Deltapilot M FMB53/ E+H Deltapilot S FMB70/ E+H Waterpilot FMX21/
E+H Cerabar M PMC51/ E+H Cerabar M PMP51/ E+H Cerabar M PMP55/ E+H Cerabar S PMC71/ E+H Cerabar S PMP71/E+H Cerabar S PMP75/ E+H Cerabar T PMC131/ E+H Cerabar T PMP131/ E+H Cerabar T PMP135/E+H Ceraphant T PTC31/E+H Ceraphant T PTP31/ E+H Ceraphant T PTP35/
saleMan 1:
saleMan 2:
saleMan 3:
saleMan 4: