EJX210A Flange Mounted Differential Pressure Transmitter
  Yokogawa EJA210A and Vokogawa EJA220A flange installation type differential pressure transmitter used to measure the liquid containing solid and precipitation and the liquid level and density of steam, then transform it into a 4-20 madc current signal o
Description

1、Technical specifications

EJX210A Mounted differential pressure transmitter
Type M capsule H capsule
Measurement span -100 ~ 100 kPa -500 ~ 500 kPa
(-400 ~ 400 inH2O) (-2000 ~ 2000 inH2O)
Measurement range 1 ~ 100 kPa 5 ~ 500 kPa
(4 ~ 400 inH2O) (20 ~ 2000 inH2O)
Accuracy ±0.075% ±0.075%
Level of protection IP67, NEMA 4X, JIS C0920 immersion type
Explosion-proof insructure FM, CENELEC ATEX, CSA
Output signal 4 ~ 20 mA DC 或FOUNDATION™ fieldbus
power 10.5 ~ 42 V DC (本安型: 10.5 ~ 30 V DC)
Environment temperature -40 ~ 85 ℃(-40 ~ 185 °F) (normal)
-10 ~ 85 ℃(14 ~ 185 °F) (High temperature type)
-30 ~ 80 ℃(-22 ~ 176 °F ) (With built-in display table)
Process temperature -40 ~ 120 ℃(-40 ~ 248 °F) (normal)
-10 ~ 250 ℃(14 ~ 482 °F) (High temperature type)
The maximum pressure Flange nominal pressure
installation Flange installation
Process flange dimensions Flat type 3″(80 mm), 2″(50 mm), 1 1/2″(40 mm)
Convex type: 4″(100 mm), 3″(80 mm)
High voltage side of the membrane material SUS316L, hastelloy C-276, tantalum
Amplifier material Cast aluminum alloy

2、Selection table

  Basic specification code:EJA220A-DMSJ12G5A-92NN

  EJA220A------- Flange-mounted differential pressure transmitter (Extended diaphragm type)

Output Signal
-D 4 to 20 mA DC with digital communication (BRAIN protocol)
-E 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E)
-F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C22T02-00E)
-G Digital communication (PROFIBUS PA protocol, refer to GS 01C22T03-00E)
Measurement span
(capsule)
M 1-100KPa
H 5-500KPa
High pressure side
(Process flange side)
wetted parts material*1*5
[Diaphragm]      [Pipe]            [Others]
S*2  # SUS316L        SUS316         SUS316*8
W*3 # Hastelloy C-276*6  SUS316   SUS316*8
Process flange rating
J1 JIS 10K
J2 JIS 20K
A1 ANSI Class 150  P1 . . . . . . . . . . JPI Class150
A2 ANSI Class 300  P2 . . . . . . . . . . JPI Class 300
D2 DIN PN10/16
D4 DIN PN25/40
Diaphragm extensionlength (X2)
☆2 X2=50mm
4 X2=100mm
6 X2=150mm
Process flange
size/material
☆G 4-inch (100 mm) / S25C
H 4-inch (100 mm) / SUS304*9
J 4-inch (100 mm) / SUS316*10
D 3-inch (80 mm) / S25C
E 3-inch (80 mm) / SUS304*9
F 3-inch (80 mm) / SUS316*10
Low pressure side process
connection
0 without process connector (Rc1/4 female on the cover flanges)
1 with Rc1/4 female process connector
2 with Rc1/2 female process connector
3 with 1/4 NPT female process connector
4 with 1/2 NPT female process connector
☆5 without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material
☆A SCM435
B SUS630
C SUH660
Installation
-9 Horizontal impulse piping type, left side high pressure
Electrical connection
0 G1/2 female, one electrical connection
☆2 1/2 NPT female, two electrical connections without blind plug
3 Pg 13.5 female, two electrical connections without blind plug
4 M20 female, two electrical connections without blind plug
5 G1/2 female, two electrical connections and a blind plug *7
7 1/2 NPT female, two electrical connections and a blind plug *7
8 Pg 13.5 female, two electrical connections and a blind plug *7
9 M20 female, two electrical connections and a blind plug *7
A G1/2 female, two electrical connections and a SUS316 blind plug
C 1/2 NPT female, two electrical connections and a SUS316 blind plug
D M20 female, two electrical connections and a SUS316 blind plug
Integral indicator
D Digital indicator
E Digital indicator with the range setting switch*4
☆N (None)
-
N Always N

  The‘☆’marks indicate the most typical selection for each specification.Example: EJA220A-DMSA12G5A-92NN/

  The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use ofSUS316 material,there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.

  *1:Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,Capsule; SUS316L(Diaphragm, Hastelloy C-276 or ASTM N10276), Vent plug; SUS316

  *2:Applicable for 4-inch (100 mm) flange size (Process flange size/material G, H and J).

  *3:Applicable for 3-inch (80 mm) flange size (Process flange size/material D, E and F).

  *4:Not applicable for Output signal code F and G.

  *5:Users must consider the characteristics of selected wetted parts material and the influence of process fluids.Theuse of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids.Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid,hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150 °C [302 °F] or above). Contact Yokogawa for detailed information of the wetted parts material.

  *6:Hastelloy C-276 or ASTM N10276.

  *7:Not applicable when option code /E1 is specified.

  *8:SUS316 or ASTM grade 316.

  *9:SUS304 or ASTM grade 304. Forged version may be used.

  *10:SUS316 or ASTM grade 316. Forged version may be used
EJA110A Differential pressure transmitter/EJA118W/EJA118Y/EJA118N Double flanges differential pressure transmitter/EJA120A micro differential pressure transmitter/ EJA130A High performance differential pressure transmitter/EJA210A/EJA220A  Flange Mounted Differential Pressure Transmitter/ EJA310A Absolute Pressure Transmitter/ EJA430A Gauge Pressure Transmitter/ EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters/ Model EJA440A High Pressure Transmitter/EJA510A and EJA530A Absolute and Gauge Pressure Transmitters/Model EJX110A Differential pressure transmitter/EJX118W Diaphragm Sealed Differential Pressure Transmitters/EJX210A Flange Mounted Differential Pressure Transmitter/EJX430A Gauge pressure transmitter/ EJX438A Diaphragm seal pressure transmitter/EJX910A Multivariable Pressure Transmitter
. EJA110A Differential pressure transmitter/EJA118W/EJA118Y/EJA118N Double flanges differential pressure transmitter/EJA120A micro differential pressure transmitter/ EJA130A High performance differential pressure transmitter/EJA210A/EJA220A  Flange Mounted Differential Pressure Transmitter/ EJA310A Absolute Pressure Transmitter/ EJA430A Gauge Pressure Transmitter/ EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters/ Model EJA440A High Pressure Transmitter/EJA510A and EJA530A Absolute and Gauge Pressure Transmitters/Model EJX110A Differential pressure transmitter/EJX118W Diaphragm Sealed Differential Pressure Transmitters/EJX210A Flange Mounted Differential Pressure Transmitter/EJX430A Gauge pressure transmitter/ EJX438A Diaphragm seal pressure transmitter/EJX910A Multivariable Pressure Transmitter
 