EJX210A Flange Mounted Differential Pressure Transmitter
The high performance flange mounted differential pressure transmitter EJX210A can be used to measure levels of densities of solidifying or precipitating liquids.
Description

  1 product

  The high performance flange mounted differential pressure transmitter EJX210A can be used to measure levels of densities of solidifying or precipitating liquids. EJX210A outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure.

  Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, and diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormality as an impulse line blockage.

  FOUNDATION Fieldbus protocol type is also available. All EJX series models in their standard configuration, with the exception of the Fieldbus type, are certified by TÜV as complying with SIL 2 for safety requirement.

  2 specification
 

  EJX210A Flange Mounted Differential Pressure Transmitter
M capsule H capsule
Measuring range -100~100kPa
(-400~400inH2O)
-500~500kPa
(-2000~2000inH2O)
Measuring span 1~100kPa
(4~400inH2O)
5~500kPa
(20~2000inH2O)
Accuracy ±0.075% ±0.075%
Protection grade IP67,NEMA 4X, JIS C0920immersion type
Explosion-proof specifications FM,CENELEC ATEX,CSA,IECEx
output signal 4~20mA DCi,FOUNDATION™Field bus, two wire system of digital communication
Power BRAIN, HART: 10.5~42V DC
(EExi: 10.5~30V DC)
Fieldbus: 9~32V DC
(EExi Entity: 9~24V DC,EExi FISCO: 9~17.5V DC)
environment temperature -40~85℃(-40~185℉) (ordinary)
-10~85℃(14~185℉) (High temperature type used)
-30~80℃(-22~176℉) (Built-in indicator in)
process temperature -40~120℃(-40~248℉) (ordinary)
-10~250℃(14~482℉) (High temperature type used)
The maximum working pressure Flange pressure rated
Installation Flange installation
Flange size Flat flange type: 3-inch (80mm),2-inch (50mm),1 1/2-inch (40mm)
The convex flange type: 4-inch (100mm),3-inch (80mm)
Diaphragm material (high side) SUS316L,Hartz alloy C - 276, tantalum material
The flange material S25C,SUS304,SUS316
The shell Aluminum alloy or ASTM CF - 8 m stainless steel (optional)
saleMan 1:
saleMan 2:
saleMan 3:
saleMan 4: