1. Product
The high performance EJX930A multivariable transmitter features a single-crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam mass flow. The EJX930A outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure, static pressure, process temperature, or dynamically calculated and fully compensated mass flow.
FOUNDATION fieldbus protocol type is also available.
Key features:
• 1.0% mass flow rate accuracy over 1:10 flow range
• Advanced diagnostic function (option) [HART protocol type]
• Simultaneous dual output of 4 to 20mA and pulse signals.
• HART protocol revision selectable from 5 (HART 5) or 7 (HART 7)
• Long tag supporting up to 32 characters (HART 7)
• Enhanced burst mode and event notification(HART 7)
• SIL2 for safety requirement Note: HART 5 stands for HART protocol revision 5 HART 7 stands for HART protocol revision 7 [FOUNDATION Fieldbus protocol type]
• Various function blocks available; 5 AIs, AR, IT, SC, and IS as standard. PID as an optional feature.
• Cyclically displays up to 10 variables
• Software download function (option)
2.specification
EJX930AMultivariable Transmitter | |||||
Mcapsule | Hcapsule | ||||
Measuring range | Differential pressure |
-100~100kPa (-400~400inH2O) |
-500~500kPa (-2000~2000inH2O) |
||
Static pressure | Absolute pressure | 0~32MPa abs (0~4500psia) | |||
Gauge pressure | -0.1~32MPa (-14.5~4500psig) | ||||
External temperature | -200~800℃(-328~1472℉) | ||||
Measuring range | Differential pressure |
1~100kPa (4~400inH2O) |
5~500kPa (20~2000inH2O) |
||
Static pressure | absolute/pressure | 1~32MPa(145~4500psi) | |||
External temperature | 10~1050℃(18~1890℉) | ||||
精度 | Mass flow rate | ±1.0% | |||
Differential pressure | ±0.04% | ||||
Static pressure | ±0.1% | ||||
External temperature | ±0.5℃(±0.9℉) | ||||
Flow calculation reference | Main equipment | Orifice |
ISO 5167-1:1991,ISO 5167-2:2003, ASME MFC-3M-1989 |
||
Nozzle |
ISO 5167-1:1991,ISO 5167-3:2003, ASME MFC-3M-1989 |
||||
Venture tube |
ISO 5167-1:1991,ISO 5167-4:2003, ASME MFC-3M-1989 |
||||
Fluid density compensation | Ordinary fluid | DIPPR (physical properties database) | |||
Natural gas | AGA No. 8,ISO 12213 | ||||
Steam | IAPWS-IF97 Water and Steam,1997 | ||||
Manual mode | Manually enter the flow coefficient | ||||
Protection grade | IP67,NEMA 4X, JIS C0920immersion type | ||||
Explosion-proof specifications | FM,CENELEC ATEX,IECEx | ||||
output signal |
[HARTcommunication protocol type] 4~20mAsignal and pulse signal [FOUNDATION™Field bus communication type] FOUNDATION™Field bus, two wire system of digital communication |
||||
Power |
HART:10.5~42V DC (EExi: 10.5~30V DC) Fieldbus: 9~32V DC |
||||
environment temperature |
-40~85℃(-40~185℉)(ordinary) -30~80℃(-22~176℉)(Built-in indicator in) |
||||
process temperature | -40~120℃(-40~248℉)(ordinary) | ||||
The maximum working pressure | 32MPa(4500psi) | ||||
Installation | 2-inch pipe installation | ||||
Wetted | Capsule | 316L SST(diaphragm: Ha C-276) | |||
Chamber flange | 316 SST | ||||
The shell | Aluminum alloy | ||||
The shell |
EJXMVTool™ Mass flow configuration software (FSA120) |