1.The characteristics of EJX high performance transmitter:
Adopt single crystal silicon resonant sensor technology range of application:Liquids, gases, liquid level, density, and pressure measurement;EJX110A precision0.04% The impact pressure limit69MPA /The maximum pressure:
L---16MPA;M,H----25MPA
model selection guide:
EJX110Aoutput signal –D;-E;-F,measuring span:-L 0.1-10KPA;-M0.5-100KPA;-H 2.5-500KPA
2、Products selection data
EJX110A differential pressure transmitter | |||
L capsule | M capsule | H capsule | |
Measurement span | -10 ~ 10 kPa | -100 ~100 kPa | -500 ~ 500 kPa |
(-40 ~ 40 inH2O) | (-400 ~ 400 inH2O) | (-2000 ~ 2000 inH2O) | |
Measurement range | 0.1 ~ 10 kPa | 0.5 ~ 100 kPa | 2.5 ~ 500 kPa |
(0.4 ~ 40 inH2O) | (2 ~ 400 inH2O) | (10 ~ 2000 inH2O) | |
Accuracy | ±0.04% | ±0.04% | ±0.04% |
Level of protection | IP67, NEMA 4X, JIS C0920immersion type | ||
Explosion-proof structure | FM, CENELEC ATEX, CSA | ||
Output signal | 4 ~ 20 mA DC or FUNDATION™ filedbus | ||
Power | 10.5 ~ 42 V DC (intrinsic safety type: 10.5 ~ 30 V DC) |