Rosemount 3051L Liquid level transmitter
  Rosemount 3051 liquid level transmitters combine the features and benefits of a 3051 transmitter with the durability and reliability of a direct mount seal all in a single model number. Level transmitters can also be ordered with an additional 1199 remo
Description

1. Product performance

  Rosemount 3051 liquid level transmitters combine the features and benefits of a 3051 transmitter with the durability and reliability of a direct mount seal all in a single model number. Level transmitters can also be ordered with an additional 1199 remote seal to form a Tuned-System Assembly that offers improved performance and reduced costs compared to traditional symmetrical (balanced) assemblies. Product features and capabilities include:

  Variety of process connections

  Quantified performance for the entire transmitter / seal assembly (QZ option)

  4-20 mA HART, 1-5 Vdc HART low power, FOUNDATION fieldbus, and Profibus PA protocols

2. Technical data

  Superior performance: accuracy0.04%, range rate 100:1

  Differential pressure:from 0.1 in water to 2000 psi

  Table pressure:from 2.5 in water to 2000 psi

  Small in size, light weight but strong, easy to install.

  3051TExcellent performance: accuracy is 0.04%

  Differential pressure:from 0.3 in water to 10,000 psi

  Table pressure: from 0.3 in water to 10,000 psi

  3051LMeasure accuracy:0.075%Small in size, light weight but strong, easy to install.Wetted parts

  material :stainless steel, ha's alloy and tantalum

3. product

Rosemount Flange-Mounted Liquid Level Transmitter
3051L Flange-Mounted Liquid Level Transmitter
Code PRESSURERANGES(RANGE/MIN. SPAN)
2 –250 to 250 inH2O/2.5 inH2O (–0,6 to 0,6 bar/6,2 mbar)
3 –1000 to 1000 inH2O/10 inH2O (–2,5 to 2,5 bar/25 mbar)
4 –300 to 300 psi/3 psi (–20,7 to 20,7 bar/0,2 bar)
Code Output
A 4–20 mA with Digital Signal Based on HART Protocol
M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output)
NOTE: Not available with hazardous certification Option Codes I1, N1, E4, K6, and K8.
F FOUNDATION fieldbus Protocol
W(1) Profibus PA Protocol
M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output)
Code Process Connection Size Material Extension Length 注释
G0(2) 2-in./DN 50 316L SST Flush Mount Only Out parts accord with the Schedule 80 pipe diameter size. About the Schedule 40 pipe size, please consult factory.
H0(2) 2-in./DN 50 Alloy C-276 Flush Mount Only
J0 2-in./DN 50 Tantalum Flush Mount Only
A0(2) 3-in./DN 80 316L SST Flush Mount
A2(2) 3-in./DN 80 316L SST 2-in./50 mm
A4(2) 3-in./DN 80 316L SST 4-in./100 mm
A6(2) 3-in./DN 80 316L SST 6-in./150 mm
B0(2) 4-in./DN 100 316L SST Flush Mount
B2(2) 4-in./DN 100 316L SST 2-in./50 mm
B4(2) 4-in./DN 100 316L SST 4-in./100 mm
B6(2) 4-in./DN 100 316L SST 6-in./150 mm
C0(2) 3-in./DN 80 Alloy C-276 Flush Mount
C2(2) 3-in./DN 80 Alloy C-276 2-in./50 mm
C4(2) 3-in./DN 80 Alloy C-276 4-in./100 mm
C6(2) 3-in./DN 80 Alloy C-276 6-in./150 mm
D0(2) 4-in./DN 100 Alloy C-276 Flush Mount
D2(2) 4-in./DN 100 Alloy C-276 2-in./50 mm
D4(2) 4-in./DN 100 Alloy C-276 4-in./100 mm
D6(2) 4-in./DN 100 Alloy C-276 6-in./150 mm
E0 3-in./DN 80 Tantalum Flush Mount Only
F0 4-in./DN 100 Tantalum Flush Mount Only

Code Size ASME B 16.5 (ANSI)
or DIN Flange Rating
Material Patch size is suitable for the high pressure side
M 2-in. ANSI/ASME B16.5 Class 150 CS 2 in./DN50
A 3-in. ANSI/ASME B16.5 Class 150 CS 3 in./DN80
B       4 in./DN100
N       2 in./DN50
C       3 in./DN80
D       4 in./DN100
P       2 in./DN50
E       3 in./DN80
X(2)       2 in./DN50
F(2)       3 in./DN80
G(2)       4 in./DN100
Y(2)       2 in./DN50
H(2)       3 in./DN80
J(2)       4 in./DN100
Z(2)       2 in./DN50
L(2)       3 in./DN80
Q       2 in./DN50
R       3 in./DN80
S       4 in./DN100
V       4 in./DN100
K(2)       2 in./DN50
T(2)       3 in./DN80
U(2)       4 in./DN100
W(2)       4 in./DN100
7(2)        
 
Code Process Fill-High Pressure Side Temperature Limits
A Syltherm XLT –100 to 300 °F (–73 to 135 °C)
C D. C. Silicone 704 60 to 400 °F (15 to 205 °C)
D D. C. Silicone 200 –40 to 400 °F (–40 to 205 °C)
H Inert (Halocarbon) –50 to 350 °F (–45 to 177 °C)
G Glycerine and Water 0 to 200 °F (–17 to 93 °C)
N Neobee M-200 0 to 400 °F (–17 to 205 °C)
P Propylene Glycol and Water 0 to 200 °F (–17 to 93 °C)
Code LOW PRESSURE SIDE Configuration Flange Adapter Diaphragm Material Sensor Fill Fluid
11 Gage SST 316 SST Silicone
21 Differential SST 316 SST Silicone
22 Differential SST Hastelloy C-276 Silicone
2A Differential SST 316 SST Inert (Halocarbon)
2B Differential SST Hastelloy C-276 Inert (Halocarbon)
31 Remote Seal SST 316 SST Silicone (Requires Option Code S1)

  Rosemount 3051L pressure transmitter’s special medel:

  3051L2AG0RD21AAK5M5Q4

  3051L2AH0KD21AAM5

  3051L3AA0FD21AB

 
Rosemount 1199 remote seal systems/Rosemount 148 temperature transmitter/ Rosemount 248 Temperature Transmitter/Rosemount HART 475 Field Communicator/Rosemount 644 temperature transmitter/Rosemount 1151pressure transmitter/Rosemount 2051CD differential pressure transmitter/ Rosemount 2051CG pressure transmitter/ Rosemount 2051L liquid level Transmitter/ Rosemount 2051TG pressure transmitter/ Rosemount 2088 pressure transmitter/ Rosemount 2090 pressure transmitter/Rosemount 3051C differential pressure transmitter/Rosemount 3051GP pressure transmitter/Rosemount 3051L liquid level transmitter/ Rosemount 3051S high accuracy transmitter/ Rosemount 3051T pressure transmitter/ Rosemount 3095 quality of multi-parameter transmitter/Rosemount 3144temperature transmitter/Rosemount integrated valve group
 

saleMan 1:
saleMan 2:
saleMan 3:
saleMan 4: