1、 Product description
Rosemount pressure transmitter has a range of products, each product has different characteristics. 3051TG/TA Rosemount pressure transmitter is a test of the power industry after 40 years of Rosemount pressure transmitter in one of the series. High reliability, long-term stability and easy maintenance design. 3051TG Rosemount pressure transmitter from design to installation, from maintenance to operations can optimize the measurement concept. Rosemount 3051T-type gauge pressure and absolute pressure transmitter assembly sensors, electronics and single-diaphragm design and integration, to achieve gauge and absolute pressure measurement of the calibration range from 0.3 to 10000psi. 3051TG absolute pressure transmitters and pressure transmitters are 3051TA compact products. User-friendly on-site installation, for the use of small space is very high
2、Product feature
Rosemount 3051T In-line Pressure transmitters provide reliable Gage and Absolute pressure measurement in a compact in-line design. Select from the following capabilities for seamless integration:
Performance up to 0.04% accuracy
Manifolds and Seal Solutions
4-20 mA HART, 1-5 Vdc HART low power, FOUNDATION fieldbus, and
Profibus PA protocols
· Calibrated spans/ranges from 0.3 to 10,000 psi (10,3 mbar to 689 bar)
· 316 SST and Alloy C-276 process isolators
3、 Technical data
Overall performance: ± 0.15% FS
Accuracy: ± 0.075% FS
Absolute pressure: calibration range from 0.3 to 10000psi
Gauge pressure: calibration range from 0.3 to 10000psi
CR stainless steel with Hastelloy process diaphragm
Single-diaphragm design
Fill Fluid: Silicone oil with inert
Optional DIN connection with the Autoclave process of matching
4、the model selection data:
Model | Pressure transmitter type | |||
3051TG | Pressure Transmitter | |||
3051TA | Absolute pressure transimitter | |||
Code |
|
|||
1
2 3 4 5 |
|
|||
Code | Output | |||
A
M(1)
|
4–20 mA with Digital Signal Based on HART Protocol M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output) NOTE: Not available with hazardous certification Option Co des I1, N1, E4, K6 or K8. |
|||
Code | Process connection style | |||
2A
2B
2C 2F 61 |
¼–18 NPT Female ½–14 NPT Female G½ A DIN 16288 Male (Available in SST for Range 1–4 only) Coned and Threaded, Compatible with Autoclave Type F-250-C Non-threaded Instrument flange (Available in Range 1–4 only) |
|||
Code |
|
|||
2(2)
3(3)
|
|
|||
Code | Fill Fluid | |||
1
2 |
Silicone Inert |
|||
Code |
|
|||
A
B
C D J K L M |
|
The model of Rosemount 3051TG/TA pressure transmitter
Rosemount 1199 remote seal systems/Rosemount 148 temperature transmitter/ Rosemount 248 Temperature Transmitter/Rosemount HART 475 Field Communicator/Rosemount 644 temperature transmitter/Rosemount 1151pressure transmitter/Rosemount 2051CD differential pressure transmitter/ Rosemount 2051CG pressure transmitter/ Rosemount 2051L liquid level Transmitter/ Rosemount 2051TG pressure transmitter/ Rosemount 2088 pressure transmitter/ Rosemount 2090 pressure transmitter/Rosemount 3051C differential pressure transmitter/Rosemount 3051GP pressure transmitter/Rosemount 3051L liquid level transmitter/ Rosemount 3051S high accuracy transmitter/ Rosemount 3051T pressure transmitter/ Rosemount 3095 quality of multi-parameter transmitter/Rosemount 3144temperature transmitter/Rosemount integrated valve group