1、 Product details:
Agreement with Rosemount 3144P HART temperature transmitter with superior accuracy, stability and reliability, making it a control / security applications in the industry-leading temperature transmitter. Rosemount 3144P has the support of a single sensor input and the dual capacity of dual-sensor input. Dual sensor input capability allows the transmitter to the sensor simultaneously from two independent receiver input signal. Dual-sensor configuration can be used to measure temperature, average temperature or for redundant temperature measurement.Used to control / security of the optimal temperature transmitter A transmitter also has support for single sensor and dual sensor capabilities
Enhance the ability of anti-EMI and filter measurements in the process to ensure excellent stability
Safety Instrumented Systems by IEC61508 (SIS) of the third-party measurement certification
Industry-leading 5-year stability and reduce maintenance costs
Hot Backup ? and sensor drift warning feature can improve the measurement of long-term reliability
Match the transmitter and sensor interchangeability of the sensor to eliminate errors, improve the measurement accuracy of 75%
Even in the harsh environment, the two-chamber housing also ensures the highest reliability
Integration of the large LCD meter display, easy reading
2、Key technical index
Digital Accuracy | ±0.10° C (±0.18° F) for Pt100 RTD |
D/A Accuracy | ±0.02% of span (Applies to HART/4-20 mA devices) |
Ambient Temperature Effects | 0.0015 °C (+0.001% of span for HART/4-20 mA devices) per 1.0 °C (1.8 °F) change in ambient for a Pt100 RTD |
Stability (RTDs) |
±0.1% of reading or 0.1° C, whichever is greater, for two years ±0.25% of reading or 0.25° C, whichever is greater, for five years |
Input | Two Independently Configured Inputs; 2-, 3-, and 4-wire RTD, and Ohm, Thermocouple, Millivolt |
Output | 4-20 mA/HART or FOUNDATION fieldbus signal |
Supply Voltage | 12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required) |
3、specification
Digital precision | Pt100 RTD,it’s +0.10 °C (+0.18 °F) |
D/A accuracy | +0.02% span spacing |
effect of ambient temperature | The environment temperature change 1.0 °C,Pt100 RTD the temperature is 0.0015°C |
Stability | RTD Two years precision, in the + 0.1% reading or supplied shall prevail in the 0.1 ° C, the precision of RTD five years, in the readings or 0.25 ° C + 0.25% for highly actie shall prevail |
Input | 2, 3, 4 wire RTD, thermocouple, mV or ohm |
Output | 4-20 mA dc,Using HART protocol |
Pover | 12.0 至42.4 V dc(250 ohm 18.1 V dc ) |