  The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe.
Description

  一、 Product Information

  The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing and correlation detection method, US300FM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids. Easy setup with interactive parameter setting. Easy adjustment with no zero-offset transducers

  二、 Features

  More accurate measurements under difficult conditions

  New noise suppression technique improves accuracy of measurements with fluids where air bubbles are present

  Fast response

  Yokogawa signal processing technology improves the speed and accuracy of measurements

  Easy installation and adjustment of transducers

  Transducers are small and light – can be held in one hand

  Each sensor calibrated before shipment, eliminating need to tune on-site

  No longer necessary to adjust the zero flow condition

  Easy setup with interactive parameter setting process

  Two flow-input channels are provided as an option

  A maximum of two current outputs enable the simultaneous measurement of flow and sound velocity

  三、 Specifications

  US300FM Performance

Fluid Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s)
Measured values Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid (when optional wall thickness probe is provided)
Pipe size 25 to 6,500 mm
Pipe material Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc.
Flow velocity range 0.01 to 25 m/s
Fluid temperature range -30 deg to +130 deg C. (general use)
-30 deg to +200 deg C. (high-temperature use)
Accuracy 1% to 3% of reading (depends on application)
Straight pipe run upstream More than 10 D (depends on the piping conditions)